Adyaa
Home
About Us
Sensors
HVAC
CO2 Sensor
Air Velocity Transmitter
Humidity and Temperature
Dew Point Sensor
Sensor Hub
Moisture in oil
OEM
Coating Thickness
EC770SE
EC500A
EC555
EC100S
EC770P
EC777E
EC900
EC770XE
EC470B
Elcometer 456
Industrial Sensors
Baumer
Baumer Encoders
Analyzers
ABB Continuous
Instrumentation
Pressure
Baumer Pressure Transmitter
AAB Pressure Transmitter
Level
ABB Level Sensors
UWT Level Sensors
Flow
ABB Flow Meter
Baumer Flow Sensor
E+E Flow Sensor
Automation
Industrial Automation
ABB Drives
ABB PLC
Services
Tecell Software
Calibration
Blog
Products
Sensors
Instrumentation
Automation
IoT
Marking System
Pressure Relief
Contact
Home
About Us
Sensors
HVAC
CO2 Sensor
Air Velocity Transmitter
Humidity and Temperature
Dew Point Sensor
Sensor Hub
Moisture in oil
OEM
Coating Thickness
EC770SE
EC500A
EC555
EC100S
EC770P
EC777E
EC900
EC770XE
EC470B
Elcometer 456
Industrial Sensors
Baumer
Baumer Encoders
Analyzers
ABB Continuous
Instrumentation
Pressure
Baumer Pressure Transmitter
AAB Pressure Transmitter
Level
ABB Level Sensors
UWT Level Sensors
Flow
ABB Flow Meter
Baumer Flow Sensor
E+E Flow Sensor
Automation
Industrial Automation
ABB Drives
ABB PLC
Services
Tecell Software
Calibration
Blog
Products
Sensors
Instrumentation
Automation
IoT
Marking System
Pressure Relief
Contact
Highly accurate pressure sensor for demanding railway applications
PBMR
Fully welded, oil-filled measuring cell
Robust stainless steel housing
Excellent accuracy and long-term stability up to ≤ 0.1% FS
Approved for railroad applications according to EN 50155
Resistant to vibration and shocks according to EN 61373 (category 2)
Absolute pressure, relative pressure, and vacuum measurement
Pressure measurement range -1 ... 40 bar
Technical Data
Measuring range
-1 … 40 bar
Min. measuring span
0.1 bar
Max. measuring span
40 bar
Pressure type
Absolute
Relative (gauged)
Standard error of measurement (BFSL)
± 0.04 % FSR
± 0.1 % FSR
Including non-linearity, hysteresis and non-repeatability according BFSL
For turndown, multiply this value by the applied turndown ratio
Max. measuring error
± 0.1 % FSR
± 0.25 % FSR
Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
For turndown, multiply this value by the applied turndown ratio
Temperature coefficient
≤ 0.03 % FSR/10 K , measuring span
≤ 0.03 % FSR/10 K , zero point
Compensated temperature range
-40 … 85 °C
Long term stability
≤ 0.1 % FSR/a , measuring range > 1 bar
≤ 1 mbar , measuring range ≤ 1 bar
Rise time (10 ... 90 %)
≤ 5 ms