Adyaa
Home
About Us
Sensors
HVAC
CO2 Sensor
Air Velocity Transmitter
Humidity and Temperature
Dew Point Sensor
Sensor Hub
Moisture in oil
OEM
Coating Thickness
EC770SE
EC500A
EC555
EC100S
EC770P
EC777E
EC900
EC770XE
EC470B
Elcometer 456
Industrial Sensors
Baumer
Baumer Encoders
Analyzers
ABB Continuous
Instrumentation
Pressure
Baumer Pressure Transmitter
AAB Pressure Transmitter
Level
ABB Level Sensors
UWT Level Sensors
Flow
ABB Flow Meter
Baumer Flow Sensor
E+E Flow Sensor
Automation
Industrial Automation
ABB Drives
ABB PLC
Services
Tecell Software
Calibration
Blog
Products
Sensors
Instrumentation
Automation
IoT
Marking System
Pressure Relief
Contact
Home
About Us
Sensors
HVAC
CO2 Sensor
Air Velocity Transmitter
Humidity and Temperature
Dew Point Sensor
Sensor Hub
Moisture in oil
OEM
Coating Thickness
EC770SE
EC500A
EC555
EC100S
EC770P
EC777E
EC900
EC770XE
EC470B
Elcometer 456
Industrial Sensors
Baumer
Baumer Encoders
Analyzers
ABB Continuous
Instrumentation
Pressure
Baumer Pressure Transmitter
AAB Pressure Transmitter
Level
ABB Level Sensors
UWT Level Sensors
Flow
ABB Flow Meter
Baumer Flow Sensor
E+E Flow Sensor
Automation
Industrial Automation
ABB Drives
ABB PLC
Services
Tecell Software
Calibration
Blog
Products
Sensors
Instrumentation
Automation
IoT
Marking System
Pressure Relief
Contact
Precise pressure sensor for process applications
PP20S Process
Fully welded process connection
Robust stainless steel housing
Excellent temperature stability
Pressure measuring ranges from -1 ... 0 to 0 ... 40 bar
Precision class ≤ 0.5% FS
Absolute pressure, relative pressure, and vacuum measurement
IO-Link Dual Channel for easy commissioning and acquisition of valuable secondary data
Technical Data
Measuring range
-1 … 40 bar
Min. measuring span
0.4 bar
Max. measuring span
40 bar
Pressure type
Absolute
Relative (gauged)
Standard error of measurement (BFSL)
± 0.2 % FSR
± 0.5 % FSR , 0 … 0.4 bar
Including non-linearity, hysteresis and non-repeatability according BFSL
Max. measuring error
± 0.5 % FSR
± 1.0 % FSR , 0 … 0.4 bar
Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
Temperature coefficient
≤ 0.2 % FSR/10 K , measuring span
≤ 0.2 % FSR/10 K , zero point
Compensated temperature range
-20 … 125 °C
Long term stability
≤ 0.2 % FSR/a
Rise time (10 ... 90 %)
≤ 20 ms
IO-Link interface
IO-Link version
1.1
Device profile
Smart Sensor Profile
IO-Link port type
Class A
Baud rate
38,4 kbaud (COM2)
SIO-mode
Yes
Process data (cyclic)
Pressure or temperature
Switch state
State of alert
Scaling factor
Diagnostic data (acyclic)
Ambient pressure
CPU temperature
Unit temperature
Operation time (since power-on)
Adjustable data (acyclic)
Offset settings
Switch parameters
Measuring mode
Dual Channel
IO-Link / Analogue
Analogue / SIO Mode