Adyaa
Home
About Us
Sensors
HVAC
CO2 Sensor
Air Velocity Transmitter
Humidity and Temperature
Dew Point Sensor
Sensor Hub
Moisture in oil
OEM
Coating Thickness
EC770SE
EC500A
EC555
EC100S
EC770P
EC777E
EC900
EC770XE
EC470B
Elcometer 456
Industrial Sensors
Baumer
Baumer Encoders
Analyzers
ABB Continuous
Instrumentation
Pressure
Baumer Pressure Transmitter
AAB Pressure Transmitter
Level
ABB Level Sensors
UWT Level Sensors
Flow
ABB Flow Meter
Baumer Flow Sensor
E+E Flow Sensor
Automation
Industrial Automation
ABB Drives
ABB PLC
Services
Tecell Software
Calibration
Blog
Products
Sensors
Instrumentation
Automation
IoT
Marking System
Pressure Relief
Contact
Home
About Us
Sensors
HVAC
CO2 Sensor
Air Velocity Transmitter
Humidity and Temperature
Dew Point Sensor
Sensor Hub
Moisture in oil
OEM
Coating Thickness
EC770SE
EC500A
EC555
EC100S
EC770P
EC777E
EC900
EC770XE
EC470B
Elcometer 456
Industrial Sensors
Baumer
Baumer Encoders
Analyzers
ABB Continuous
Instrumentation
Pressure
Baumer Pressure Transmitter
AAB Pressure Transmitter
Level
ABB Level Sensors
UWT Level Sensors
Flow
ABB Flow Meter
Baumer Flow Sensor
E+E Flow Sensor
Automation
Industrial Automation
ABB Drives
ABB PLC
Services
Tecell Software
Calibration
Blog
Products
Sensors
Instrumentation
Automation
IoT
Marking System
Pressure Relief
Contact
High-precision pressure sensor with flush clamp connection
PBMH
3-A sanitary standards, FDA-compliant, EHEDG-certified
Resistant to all common CIP cleaning media and SIP-capable (150 °C max, < 30 min)
Versions available for high media temperatures (200 °C)
Surface roughness connection Ra ≤ 0.8 for highest hygienic requirements
Fully welded and compact design for washdowns without residuals
Excellent active temperature compensation for increased process stability
External programming of zero point and span with FlexProgrammer 9701
Absolute pressure, relative pressure and vacuum measurement
Technical Specification
Measuring range
-1 … 400 bar
Min. measuring span
0.1 bar
Max. measuring span
400 bar
Pressure type
Absolute
Relative (gauged)
Standard error of measurement (BFSL)
± 0.04 % FSR
± 0.1 % FSR
Including non-linearity, hysteresis and non-repeatability according BFSL
Max. measuring error
± 0.1 % FSR
± 0.25 % FSR
Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
For turndown, multiply this value by the applied turndown ratio
Temperature coefficient
≤ 0.03 % FSR/10 K , measuring span
≤ 0.03 % FSR/10 K , zero point
Compensated temperature range
-40 … 85 °C
Long term stability
≤ 0.1 % FSR/a , measuring range > 1 bar
≤ 1 mbar , measuring range ≤ 1 bar
Max. turndown ratio
5 : 1
Rise time (10 ... 90 %)
≤ 5 ms